Updated on 2024/04/09

写真a

 
Hikaru Nemoto
 
Organization
Graduate Faculty of Interdisciplinary Research Faculty of Medicine University Hospital (Radiation Therapy Department) Assistant Professor
Title
Assistant Professor

Research History

  • University of Yamanashi

    2022.4

  • University of Yamanashi   医学部 先端医用画像学講座   特任助教

    2022.4

  • 東京都立墨東病院   診療放射線科   医学物理士

    2021.4 - 2022.3

  • 東京都立墨東病院   診療放射線科   医学物理士

    2021.4 - 2022.3

  • 東京都立駒込病院   放射線物理室   医学物理士

    2020.1 - 2021.3

  • 東京都立駒込病院   放射線物理室   医学物理士

    2020.1 - 2021.3

▼display all

Education

  • Tohoku University

    2018.4 - 2020.3

      More details

    Country: Japan

    Course: Master course

  • Tohoku University   医学系研究科   医科学専攻

    2018.4 - 2020.3

      More details

    Country: Japan

  • Tohoku University

    2014.4 - 2018.3

      More details

    Country: Japan

  • Tohoku University   医学部   保健学科

    2014.4 - 2018.3

      More details

    Country: Japan

Degree

  • 修士(医科学) ( 2020.3   東北大学 )

Research Areas

  • Life Science / Radiological sciences

  • Life Science / Radiological sciences  / Radiation science

Research Interests

  • 強度変調放射線治療

  • 医学物理

  • 放射線治療

  • 放射線治療

  • 強度変調放射線治療

  • 医学物理

Papers

  • Evaluation of the performance of both machine learning models using PET and CT radiomics for predicting recurrence following lung stereotactic body radiation therapy: A single-institutional study Reviewed Major achievement

    Nemoto, H. Saito, M. Satoh, Y. Komiyama, T. Marino, K. Aoki, S. Suzuki, H. Sano, N. Nonaka, H. Watanabe, H. Funayama, S. Onishi, H.

    Journal of Applied Clinical Medical Physics   e14322   2024.3( ISSN:1526-9914 )

     More details

    Language:English   Publishing type:Research paper (scientific journal)  

    DOI: 10.1002/acm2.14322

  • Evaluation of a New Method for CyberKnife Treatment for Central Lung and Mediastinal Tumors by Tracheobronchial Tracking Reviewed

    Suzuki, T. Saito, M. Takahashi, H. Suzuki, H. Makino, K. Ueda, K. Mochizuki, K. Mochizuki, Z. Nemoto, H. Sano, N. Onishi, H.

    Technology in cancer research & treatment   23   2024.2( ISSN:1533-0338 )

     More details

    Language:English   Publishing type:Research paper (scientific journal)  

    DOI: 10.1177/15330338241232557

  • Current status of remote radiotherapy treatment planning in Japan: findings from a national survey†

    Saito, M. Tamamoto, T. Kawashiro, S. Umezawa, R. Matsuda, M. Tohyama, N. Katsuta, Y. Kanai, T. Nemoto, H. Onishi, H.

    Journal of Radiation Research   online ahead of print   2023.11( ISSN:0449-3060 )

     More details

    Language:English   Publishing type:Research paper (scientific journal)  

    DOI: 10.1093/jrr/rrad085

  • Cycle-generative adversarial network-based bone suppression imaging for highly accurate markerless motion tracking of lung tumors for cyberknife irradiation therapy

    Mochizuki, Z. Saito, M. Suzuki, T. Mochizuki, K. Hasegawa, J. Nemoto, H. Satani, K. Takahashi, H. Onishi, H

    Journal of Applied Clinical Medical Physics   2023.11( ISSN:1526-9914 )

     More details

    Language:English   Publishing type:Research paper (scientific journal)  

    DOI: 10.1002/acm2.14212

  • 腎細胞癌に対する定位放射線治療の実際と課題 Reviewed Major achievement

    根本光 齋藤正英 大西洋

    RadFan 11月臨時増刊号「放射線治療 Book2023」   21 ( 13 )   2023.10

     More details

    Authorship:Lead author   Language:Japanese   Publishing type:Research paper (scientific journal)  

  • Dosimetric comparison of five different radiotherapy treatment planning approaches for locally advanced non-small cell lung cancer with sequential plan changes Reviewed Major achievement

    Saito, M. Komiyama, T. Marino, K. Aoki, S. Akita, T. Matsuda, M. Sano, N. Suzuki, H. Koji, U. Nemoto, H. Onishi, H.

    Thoracic Cancer   online ahead of print   2023.10( ISSN:1759-7706 )

     More details

    Language:English   Publishing type:Research paper (scientific journal)  

    DOI: 10.1111/1759-7714.15137

  • Long-term experience in quality assurance of on-rail computed tomography systems for image-guided radiotherapy using in-house multifunctional phantoms Reviewed Major achievement

    Saito, M. Sano, N. Suzuki, H. Komiyama, T. Marino, K. Ueda, K. Nemoto, H. Onishi, H.

    Radiological Physics and Technology   2023.4( ISSN:1865-0333 )

     More details

    Language:English   Publishing type:Research paper (scientific journal)  

    To report the long-term quality assurance (QA) experience of an on-rail computed tomography (CT) system for image-guided radiotherapy using an in-house phantom. An on-rail CT system combining the Elekta Synergy and Canon Aquilion LB was used. The treatment couch was shared by the linear accelerators and CT, and the couch was rotated by 180° when using the on-rail-CT system to ensure that the CT direction was toward the head. All QA analyses were performed by radiation technologists on CBCT or on-rail CT images of the in-house phantom. The CBCT center accuracy from the linac laser, couch rotational accuracy (CBCT center vs. on-rail CT center), horizontal accuracy by CT gantry shift, and remote couch shift accuracy were evaluated. This study reported the QA status of the system during the period 2014-2021. The absolute mean accuracy of couch rotation was 0.4 ± 0.28 mm, 0.44 ± 0.36 mm, and 0.37 ± 0.27 mm in the SI, RL, and AP directions, respectively. Horizontal and remote movement accuracies of the treatment couch were also within 0.5 mm of the absolute mean value. A decrease in the accuracy of couch rotation was also observed due to aging deterioration of related parts caused by the frequent use of couch rotation. The three-dimensional accuracy of on-rail CT systems derived mainly from treatment couches can be maintained within 0.5 mm with appropriate accuracy assurance for at least > 8 years.

    DOI: 10.1007/s12194-023-00718-1

    PubMed

  • Development of a dynamic motion platform with two independent drive systems for radiotherapy Major achievement

    Masahide Saito Hideyuki Kawakami Toshihiro Suzuki Hidekazu Suzuki Koji Ueda Hikaru Nemoto Naoki Sano Hiroshi Onishi

    Journal of Applied Clinical Medical Physics   2023.3( ISSN:1526-9914 )

     More details

    Language:English   Publishing type:Research paper (scientific journal)  

    DOI: 10.1002/acm2.13971

  • 遠隔放射線治療計画の利用実態とその課題 Reviewed

    齋藤正英, 玉本哲郎, 川城壮平, 梅澤玲, 松田正樹, 遠山尚紀, 金井貴幸, 勝田義之, 根本光, 柚原正直, 佐久間慶, 曽我部正幸, 前鼻航, 小林一之, 高松賢一, 大西洋

    Rad Fan 放射線治療情報 Book 2022   20 ( 13 )   77 - 80   2022.10

     More details

    Language:Japanese   Publishing type:Research paper (scientific journal)   Publisher:メディカルアイ  

  • 遠隔放射線治療計画の利用実態とその課題 Reviewed

    齋藤正英, 玉本哲郎, 川城壮平, 梅澤玲, 松田正樹, 遠山尚紀, 金井貴幸, 勝田義之, 根本光, 柚原正直, 佐久間慶, 曽我部正幸, 前鼻航, 小林一之, 高松賢一, 大西洋

    Rad Fan 放射線治療情報 Book 2022   20 ( 13 )   77 - 80   2022.10

     More details

    Language:Japanese   Publishing type:Research paper (scientific journal)   Publisher:メディカルアイ  

  • Evaluation of performance of pelvic CT-MR deformable image registration using two software programs Reviewed

    Tomoya Ishida, Noriyuki Kadoya, Shunpei Tanabe, Haruna Ohashi, Hikaru Nemoto, Suguru Dobashi, Ken Takeda, Keiichi Jingu

    JOURNAL OF RADIATION RESEARCH   62 ( 6 )   1076 - 1082   2021.9( ISSN:0449-3060 )

     More details

    Language:English   Publishing type:Research paper (scientific journal)  

  • Evaluation of performance of pelvic CT-MR deformable image registration using two software programs Reviewed

    Tomoya Ishida, Noriyuki Kadoya, Shunpei Tanabe, Haruna Ohashi, Hikaru Nemoto, Suguru Dobashi, Ken Takeda, Keiichi Jingu

    JOURNAL OF RADIATION RESEARCH   62 ( 6 )   1076 - 1082   2021.9( ISSN:0449-3060 )

     More details

    Language:English   Publishing type:Research paper (scientific journal)  

    We assessed the accuracy of deformable image registration (DIR) accuracy between CT and MR images using an open-source software (Elastix, from Utrecht Medical Center) and a commercial software (Velocity AI Ver. 3.2.0 from Varian Medical Systems, Palo Alto, CA, USA) software. Five male patients' pelvic regions were studied using publicly available CT, T1-weighted (T1w) MR, and T2-weighted (T2w) MR images. In the cost function of the Elastix, we used six DIR parameter settings with different regularization weights (Elastix0, Elastix0.01, Elastix0.1, Elastix1, Elastix10, and Elastix100). We used MR Corrected Deformable algorithm for Velocity AI. The Dice similarity coefficient (DSC) and mean distance to agreement (MDA) for the prostate, bladder, rectum and left and right femoral heads were used to evaluate DIR accuracy. Except for the bladder, most algorithms produced good DSC and MDA results for all organs. In our study, the mean DSCs for the bladder ranged from 0.75 to 0.88 (CT-T1w) and from 0.72 to 0.76 (CT-T2w). Similarly, the mean MDA ranges were 2.4 to 4.9 mm (CT-T1w), 4.6 to 5.3 mm (CT-T2w). For the Elastix, CT-T1w was outperformed CT-T2w for both DSCs and MDAs at Elastix0, Elastix0.01, and Elastix0.1. In the case of Velocity AI, no significant differences in DSC and MDA of all organs were observed. This implied that the DIR accuracy of CT and MR images might differ depending on the sequence used.

    DOI: 10.1093/jrr/rrab078

    PubMed

  • Evaluation of the dosimetric impact of heart function-based volumetric modulated arc therapy planning in patients with esophageal cancer. Reviewed

    Shohei Tanaka, Noriyuki Kadoya, Rei Umezawa, Hikaru Nemoto, Yoshiyuki Katsuta, Kengo Ito, Ken Takeda, Keiichi Jingu

    Radiological physics and technology   14 ( 3 )   279 - 287   2021.9( ISSN:1865-0333  eISSN:1865-0341 )

     More details

    Language:English   Publishing type:Research paper (scientific journal)   Publisher:Springer Science and Business Media LLC  

    Radiotherapy for esophageal cancer entails high-dose irradiation of the myocardium owing to its close anatomical proximity to the esophagus. This study aimed to evaluate the dosimetric impact of functional avoidance planning for the myocardium with volumetric-modulated arc therapy (VMAT) in patients with esophageal cancer and determine the feasibility of functional planning. Ten patients with early stage esophageal cancer were included in this study. The prescribed dose was 60 Gy administered in 30 fractions. An experienced physician contoured the left ventricle (LV) of the myocardium. For each patient, an anatomical plan (non-LV-sparing plan) and a functional plan (LV-sparing plan) were created using the VMAT. In the functional plan, the mean percentage of LV volume receiving a dose of ≥ 30 and ≥ 40 Gy was 6.0% ± 6.7% and 2.4% ± 2.7%, respectively, whereas in the anatomical plan, they were 11.7% ± 13.1% and 4.9% ± 6.5%, respectively. There were no significant differences with respect to the dose to the hottest 1 cm3 of the planning target volume (PTV) and the minimum dose of the gross tumor volume and the dosimetric parameters of other normal tissues between the anatomical and functional plans. We compared the anatomical and functional plans of patients with esophageal cancer undergoing VMAT. Our results demonstrated that the functional plan reduced the dose to the LV with no significant differences in the organs at risk and PTV, indicating that avoidance planning can be safely performed when administering VMAT in patients with esophageal cancer.

    DOI: 10.1007/s12194-021-00623-5

    PubMed

    Other Link: https://link.springer.com/article/10.1007/s12194-021-00623-5/fulltext.html

  • Evaluation of the dosimetric impact of heart function-based volumetric modulated arc therapy planning in patients with esophageal cancer Reviewed

    Shohei Tanaka, Noriyuki Kadoya, Rei Umezawa, Hikaru Nemoto, Yoshiyuki Katsuta, Kengo Ito, Ken Takeda, Keiichi Jingu

    Radiological Physics and Technology   14   279 - 287   2021.6( ISSN:1865-0341 )

     More details

    Language:English  

  • Evaluation of the dosimetric impact of heart function-based volumetric modulated arc therapy planning in patients with esophageal cancer Reviewed

    Shohei Tanaka, Noriyuki Kadoya, Rei Umezawa, Hikaru Nemoto, Yoshiyuki Katsuta, Kengo Ito, Ken Takeda, Keiichi Jingu

    Radiological Physics and Technology   14   279 - 287   2021.6( ISSN:1865-0341 )

     More details

    Language:English  

  • Dose distribution correction for the influence of magnetic field using a deep convolutional neural network for online MR-guided adaptive radiotherapy Reviewed

    Tomohiro Kajikawa, Noriyuki Kadoya, Shohei Tanaka, Hikaru Nemoto, Noriyoshi Takahashi, Takahito Chiba, Kengo Ito, Yoshiyuki Katsuta, Suguru Dobashi, Ken Takeda, Kei Yamada, Keiichi Jingu

    Physica Medica-European Journal of Medical Physics   80   186 - 192   2020.11( ISSN:1120-1797 )

     More details

    Language:English   Publishing type:Research paper (scientific journal)  

  • Dose distribution correction for the influence of magnetic field using a deep convolutional neural network for online MR-guided adaptive radiotherapy Reviewed

    Tomohiro Kajikawa, Noriyuki Kadoya, Shohei Tanaka, Hikaru Nemoto, Noriyoshi Takahashi, Takahito Chiba, Kengo Ito, Yoshiyuki Katsuta, Suguru Dobashi, Ken Takeda, Kei Yamada, Keiichi Jingu

    Physica Medica-European Journal of Medical Physics   80   186 - 192   2020.11( ISSN:1120-1797 )

     More details

    Language:English   Publishing type:Research paper (scientific journal)  

  • IMRTの患者QAにおける3Dプリンタで作成した頭頚部患者模擬ファントムの評価 医学物理

    角谷倫之, 阿部幸太, 根本光, 佐藤清和, 家子義朗, 伊藤謙吾, 土橋卓, 武田賢, 神宮啓一

    医学物理   40 ( 3 )   109 - 109   2020.9( ISSN:1345-5354 )

     More details

    Language:Japanese   Publisher:公益社団法人 日本医学物理学会  

    DOI: 10.11323/jjmp.40.3_109

    Other Link: https://doi.org/10.11323/jjmp.40.3_109

  • Evaluation of four-dimensional cone beam computed tomography ventilation images acquired with two different linear accelerators at various gantry speeds using a deformable lung phantom Reviewed

    Noriyuki Kadoya, Hikaru Nemoto, Tomohiro Kajikawa, Yujiro Nakajima, Takayuki Kanai, Yoshiro Ieko, Ryutaro Ikeda, Kiyokazu Sato, Suguru Dobashi, Ken Takeda, Keiichi Jingu

    Physica Medica-European Journal of Medical Physics   77   75 - 83   2020.8( ISSN:1120-1797 )

     More details

    Language:English   Publishing type:Research paper (scientific journal)  

  • Evaluation of four-dimensional cone beam computed tomography ventilation images acquired with two different linear accelerators at various gantry speeds using a deformable lung phantom Reviewed

    Noriyuki Kadoya, Hikaru Nemoto, Tomohiro Kajikawa, Yujiro Nakajima, Takayuki Kanai, Yoshiro Ieko, Ryutaro Ikeda, Kiyokazu Sato, Suguru Dobashi, Ken Takeda, Keiichi Jingu

    Physica Medica-European Journal of Medical Physics   77   75 - 83   2020.8( ISSN:1120-1797 )

     More details

    Language:English   Publishing type:Research paper (scientific journal)  

  • Evaluation of a 3D-printed heterogeneous anthropomorphic head and neck phantom for patient-specific quality assurance in intensity-modulated radiation therapy Reviewed

    Noriyuki Kadoya, Kota Abe, Hikaru Nemoto, Kiyokazu Sato, Yoshiro Ieko, Suguru Dobashi, Ken Takeda, Keiichi Jingu

    Radiological Physics and Technology   12   351 - 356   2019.7( ISSN:1865-0341 )

     More details

    Language:English   Publishing type:Research paper (scientific journal)  

  • Evaluation of a 3D-printed heterogeneous anthropomorphic head and neck phantom for patient-specific quality assurance in intensity-modulated radiation therapy Reviewed

    Noriyuki Kadoya, Kota Abe, Hikaru Nemoto, Kiyokazu Sato, Yoshiro Ieko, Suguru Dobashi, Ken Takeda, Keiichi Jingu

    Radiological Physics and Technology   12   351 - 356   2019.7( ISSN:1865-0341 )

     More details

    Language:English   Publishing type:Research paper (scientific journal)  

  • A convolutional neural network approach for IMRT dose distribution prediction in prostate cancer patients Reviewed

    Tomohiro Kajikawa, Noriyuki Kadoya, Kengo Ito, Yoshiki Takayama, Takahito Chiba, Seiji Tomori, Hikaru Nemoto, Suguru Dobashi, Ken Takeda, Keiichi Jingu

    JOURNAL OF RADIATION RESEARCH   60 ( 5 )   685 - 693   2019.7( ISSN:0449-3060 )

     More details

    Language:English   Publishing type:Research paper (scientific journal)  

  • A convolutional neural network approach for IMRT dose distribution prediction in prostate cancer patients Reviewed

    Tomohiro Kajikawa, Noriyuki Kadoya, Kengo Ito, Yoshiki Takayama, Takahito Chiba, Seiji Tomori, Hikaru Nemoto, Suguru Dobashi, Ken Takeda, Keiichi Jingu

    JOURNAL OF RADIATION RESEARCH   60 ( 5 )   685 - 693   2019.7( ISSN:0449-3060 )

     More details

    Language:English   Publishing type:Research paper (scientific journal)  

  • 4DCBCTを用いた経時的な肺機能変化に基づく放射線治療法の開発に向けた初期検討

    根本 光, 角谷 倫之, 梶川 智博, 中島 祐二朗, 家子 義朗, 武田 賢, 神宮 啓一

    日本放射線技術学会雑誌   74 ( 9 )   1004 - 1004   2018.9( ISSN:0369-4305  eISSN:1881-4883 )

     More details

    Language:Japanese   Publisher:(公社)日本放射線技術学会  

▼display all

Presentations

  • 山梨大学における呼吸性移動対策を伴うSBRTの実際 Major achievement

    根本光

    2023年度 多領域人材育成・放射線腫瘍学セミナー(第5回)  2024.2  埼玉医科大学がんプロ共催

     More details

    Event date: 2024.2

    Language:Japanese   Presentation type:Oral presentation(invited, special)  

    Venue:ZoomによるWebセミナー   Country:Japan  

  • AIの基本からAIツールの活用について Major achievement

    根本光

    令和5年度一般社団法人山梨県診療放射線技師会宿泊研修会  2023.12 

     More details

    Event date: 2023.12

    Language:Japanese   Presentation type:Other  

    Venue:Web配信   Country:Japan  

  • IGRT における息⽌め CBCT の収集条件に関する検討

    望月汐夏

    東京・関東支部合同研究発表大会  2023.12 

     More details

    Event date: 2023.12

    Language:Japanese   Presentation type:Oral presentation(general)  

    Venue:有明セントラルタワーホール&カンファレンス   Country:Japan  

  • 頭頸部領域におけるROIプロパゲーションとオートセグメンテーション精度向上の検証

    岩澤 正将

    日本放射線腫瘍学会第36回学術大会 Jastro 2023  2023.12 

     More details

    Event date: 2023.11 - 2023.12

    Language:Japanese   Presentation type:Poster presentation  

    Venue:パシフィコ横浜ノース   Country:Japan  

  • ET/CT Radiomicsと機械学習を用いた肺SBRT後の再発予測モデルの精度評価. Major achievement

    根本光

    日本放射線腫瘍学会第36回学術大会 Jastro 2023  2023.11  日本放射線腫瘍学会

     More details

    Event date: 2023.11 - 2023.12

    Language:Japanese   Presentation type:Oral presentation(general)  

    Venue:パシフィコ横浜ノース   Country:Japan  

  • 限局性肺腫瘍に対する定位放射線治療における照射法の違いによる肺線量の比較~肺定位照射にVMATは本当に有用か?~

    光田浩二

    第30回山梨放射線治療研究会  2023.7 

     More details

    Event date: 2023.7

    Language:Japanese   Presentation type:Oral presentation(general)  

    Venue:山梨大学医学部 シミックプラザ 及び Web配信.   Country:Japan  

  • 画像誘導放射線治療時における診療放射線技師の画像照合精度に関する検証

    鈴木秀和

    第79回日本放射線技術学会総会学術大会  2023.4 

     More details

    Event date: 2023.4

    Language:Japanese   Presentation type:Oral presentation(general)  

    Venue:パシフィコ横浜   Country:Japan  

  • 山梨大学での高精度治療の現状 SpaceOARを用いた前立腺がんに対する寡分割照射と超寡分割照射の実際 Major achievement

    根本光

    令和4年度 第67回臨床医学物理研究会 高精度放射線治療の現状  2023.3 

     More details

    Event date: 2023.3

    Language:Japanese   Presentation type:Other  

    Venue:オンライン開催   Country:Japan  

  • サイバーナイフ治療における新サイズ金属マーカーのアーチファクトと認識精度の評価

    根本光

    日本放射線腫瘍学会 第35回学術大会  2022.11 

     More details

    Event date: 2022.11

    Language:Japanese   Presentation type:Oral presentation(general)  

    Venue:リーガロイヤルホテル広島・NTTクレドホール・広島グリーンアリーナ  

  • サイバーナイフ治療における新サイズ金属マーカーのアーチファクトと認識精度の評価

    根本光

    日本放射線腫瘍学会 第35回学術大会  2022.11 

     More details

    Language:Japanese   Presentation type:Oral presentation(general)  

    Venue:リーガロイヤルホテル広島・NTTクレドホール・広島グリーンアリーナ  

  • IMRTで変わるTBIとTMLI Invited

    根本光

    第63回臨床医学物理研究会  2022.8  臨床医学物理研究会

     More details

    Event date: 2022.8

    Language:Japanese   Presentation type:Public discourse, seminar, tutorial, course, lecture and others  

  • IMRTで変わるTBIとTMLI Invited

    根本光

    第63回臨床医学物理研究会  2022.8  臨床医学物理研究会

     More details

    Language:Japanese   Presentation type:Public discourse, seminar, tutorial, course, lecture and others  

  • 最新の放射線治療の話題~当院での照射経験を含めて~ Invited

    根本光

    肺がん集学的治療連携の会 in 山梨  2022.7  アストラぜネカ

     More details

    Event date: 2022.7

    Language:Japanese   Presentation type:Oral presentation(general)  

    Venue:オンライン講演会/ベルクラシック甲府 2階「コンチェルト」  

  • 最新の放射線治療の話題~当院での照射経験を含めて~ Invited

    根本光

    肺がん集学的治療連携の会 in 山梨  2022.7  アストラぜネカ

     More details

    Language:Japanese   Presentation type:Oral presentation(general)  

    Venue:オンライン講演会/ベルクラシック甲府 2階「コンチェルト」  

  • DIR end-to-end 物理ファントムの臨床的有用性の検討

    細谷祐里、角谷倫之、根本光、田中祥平、松田匠平、武田賢、土橋卓、神宮啓一、中村光宏

    日本放射線腫瘍学会第32回学術大会  2019.11 

     More details

    Event date: 2019.11

    Language:Japanese   Presentation type:Oral presentation(general)  

  • DIR end-to-end 物理ファントムの臨床的有用性の検討

    細谷祐里, 角谷倫之, 根本光, 田中祥平, 松田匠平, 武田賢, 土橋卓, 神宮啓一, 中村光宏

    日本放射線腫瘍学会第32回学術大会  2019.11 

     More details

    Language:Japanese   Presentation type:Oral presentation(general)  

  • DIRソフトウェアのEnd to end試験用物理ファントムの開発

    角谷倫之、細谷祐里、根本光、田中祥平、松田匠平、武田賢、土橋卓、神宮啓一、中村光宏

    日本放射線腫瘍学会32回学術大会  2019.11 

     More details

    Event date: 2019.11

    Language:Japanese   Presentation type:Oral presentation(general)  

  • DIRソフトウェアのEnd to end試験用物理ファントムの開発

    角谷倫之, 細谷祐里, 根本光, 田中祥平, 松田匠平, 武田賢, 土橋卓, 神宮啓一, 中村光宏

    日本放射線腫瘍学会32回学術大会  2019.11 

     More details

    Language:Japanese   Presentation type:Oral presentation(general)  

  • Evaluation of 3D-printed heterogeneous anthropomorphic thorax phantom for patient-specific quality assurance in intensity-modulated radiation therapy

    ⑦ Hikaru Nemoto, Noriyuki Kadoya, Shohei Tanaka, Takahito Chiba, Yoshiyuki Katsuta, Shohei Matsuda, Kengo Ito, Suguru Dobashi, Ken Takeda, Rei Umezawa, Keiichi Jingu

    Asia-Oncenia Congress of Medical Physics combined with Engineering & Physical Sciences in Medicine Conference  2019.10 

     More details

    Event date: 2019.10

    Language:English   Presentation type:Oral presentation(general)  

  • Evaluation of 3D-printed heterogeneous anthropomorphic thorax phantom for patient-specific quality assurance in intensity-modulated radiation therapy

    Hikaru Nemoto, Noriyuki Kadoya, Shohei Tanaka, Takahito Chiba, Yoshiyuki Katsuta, Shohei Matsuda, Kengo Ito, Suguru Dobashi, Ken Takeda, Rei Umezawa, Keiichi Jingu

    Asia-Oncenia Congress of Medical Physics combined with Engineering & Physical Sciences in Medicine Conference  2019.10 

     More details

    Language:English   Presentation type:Oral presentation(general)  

  • Evaluation of factors that affect 4D Cone Beam CT ventilation images for adaptive functional avoidance radiothrapy International conference

    Hikaru Nemoto, Noriyuki Kadoya, Tomohiro Kajikawa, Yujiro Nakajima, Takayuki Kanai, Yoshiro Ieko, Ken Takeda, Keiichi Jingu

    61st annual meeting of AAPM  2019.7 

     More details

    Event date: 2019.7

    Language:English   Presentation type:Poster presentation  

  • Evaluation of factors that affect 4D Cone Beam CT ventilation images for adaptive functional avoidance radiothrapy International conference

    Hikaru Nemoto, Noriyuki Kadoya, Tomohiro Kajikawa, Yujiro Nakajima, Takayuki Kanai, Yoshiro Ieko, Ken Takeda, Keiichi Jingu

    61st annual meeting of AAPM  2019.7 

     More details

    Language:English   Presentation type:Poster presentation  

  • 4D-CBCT ventilation image-based VMAT plans are comparable to 4D-CT ventilation image-based plans : evaluating 4D-CBCT ventilation images

    Hikaru Nemoto, Noriyuki Kadoya, Tomohiro Kajikawa, Nakajima Yujiro, Takayuki Kanai, Yoshiro Ieko, Ken Takeda, Keiichi Jingu

    The 117th Scientific Meeting of the Japan Society of Medical Physics  2019.4 

     More details

    Event date: 2019.4

    Language:English   Presentation type:Oral presentation(general)  

  • 4D-CBCT ventilation image-based VMAT plans are comparable to 4D-CT ventilation image-based plans : evaluating 4D-CBCT ventilation images

    Hikaru Nemoto, Noriyuki Kadoya, Tomohiro Kajikawa, Nakajima Yujiro, Takayuki Kanai, Yoshiro Ieko, Ken Takeda, Keiichi Jingu

    The 117th Scientific Meeting of the Japan Society of Medical Physics  2019.4 

     More details

    Language:English   Presentation type:Oral presentation(general)  

  • Development of 4DCBCT-based lung ventilation for adaptive ventilation-guided radiotherapy International conference

    Hikaru Nemoto, Noriyuki Kadoya, Tomohiro Kajikawa, Yujiro Nakajima, Yoshiro Ieko, Ryutaro Ikeda, Ken Takeda, Keiichi Jingu

    8th Asia-Oceania Congress of Medical Physics & 16th South-East Asia Congress of Medical Physics  2018.11 

     More details

    Event date: 2018.11

    Language:English   Presentation type:Oral presentation(general)  

  • Development of 4DCBCT-based lung ventilation for adaptive ventilation-guided radiotherapy International conference

    Hikaru Nemoto, Noriyuki Kadoya, Tomohiro Kajikawa, Yujiro Nakajima, Yoshiro Ieko, Ryutaro Ikeda, Ken Takeda, Keiichi Jingu

    8th Asia-Oceania Congress of Medical Physics & 16th South-East Asia Congress of Medical Physics  2018.11 

     More details

    Language:English   Presentation type:Oral presentation(general)  

  • 4DCBCTを用いた経時的な肺機能変化に基づく放射線治療法の開発に向けた初期検討

    根本光、角谷倫之、梶川智博、中島佑二朗、家子義朗、佐藤清和、池田龍太郎、松田匠平、伊藤謙吾、土橋卓、武田賢、神宮啓一

    日本放射線腫瘍学会第31回学術大会  2018.10 

     More details

    Event date: 2018.10

    Language:Japanese   Presentation type:Oral presentation(general)  

  • 4DCBCTを用いた経時的な肺機能変化に基づく放射線治療法の開発に向けた初期検討

    根本光, 角谷倫之, 梶川智博, 中島佑二朗, 家子義朗, 佐藤清和, 池田龍太郎, 松田匠平, 伊藤謙吾, 土橋卓, 武田賢, 神宮啓一

    日本放射線腫瘍学会第31回学術大会  2018.10 

     More details

    Language:Japanese   Presentation type:Oral presentation(general)  

  • Development of Novel Heterogeneous Anthropomorphic Head and Neck Phantom Using 3D Printer for IMRT Patient Spcific Quality Asuurance International conference

    N Kadoya, K Abe, H Nemoto, K Sato, Y Ieko, K Ito, Y Takayama, T Chiba, S Dobashi, K Takeda, K Jingu

    AAPM 60th Annual Meeting and Exhibition  2018.7 

     More details

    Event date: 2018.7

    Language:English   Presentation type:Oral presentation(general)  

  • Development of Novel Heterogeneous Anthropomorphic Head and Neck Phantom Using 3D Printer for IMRT Patient Spcific Quality Asuurance International conference

    N Kadoya, K Abe, H Nemoto, K Sato, Y Ieko, K Ito, Y Takayama, T Chiba, S Dobashi, K Takeda, K Jingu

    AAPM 60th Annual Meeting and Exhibition  2018.7 

     More details

    Language:English   Presentation type:Oral presentation(general)  

▼display all

Awards

  • The 117th Scientific Meeting of JSMP President's Award Gold

    2019.4   4D-CBCT ventilation image-based VMAT plans are comparable to 4DCT ventilation image-based plans : evaluating 4D-CBCT ventilation images

     More details

    Award type:Award from international society, conference, symposium, etc. 

  • The 117th Scientific Meeting of JSMP President's Award Gold

    2019.4  

    根本光, 角谷倫之, 梶川智博, 中島祐二朗, 金井貴幸, 家子義朗, 武田賢, 神宮啓一

     More details

    Award type:Award from international society, conference, symposium, etc. 

Professional Memberships

  • 日本医学物理士会

  • 日本医学物理学会

  • 日本放射線腫瘍学会

  • 日本医学物理士会

  • 日本医学物理学会

  • 日本放射線腫瘍学会

▼display all